2.1.4 Precipitation - Lambrecht 15152
Function
In order to provide a detection of all kinds of precipitation the precipitation instru-
mentation is enlarged by the Lambrecht 15152. It is a very simple but reliable sensor
as shown in Fig. 2.8.
Figure 2.8: Lambrecht Rain Sensor 15152
[Manual - Electronic Rain Indicator 15152, 6/07]
The sensor‘s surface is heated in two levels. The first level is switched on constantly
to prevent ice and dew formation. As soon as the sensing area is moistured, the
second heating level is switched on to make sure that the surface drys up as soon as
possible. After drying up the second level is switched off again. So a use at every
weather condition is implemented.
Measuring Principle
At the beginning of a precipitation event rain drops will cause a conductive connec-
tion between the two sensing electrodes to trigger the relay contacts. By this means
a relay is cut through and the controlling event is done. The SPS process this event
for further protection steps.