Chapter 5 ________________________________________ Advanced Use of Lizard Setup Software
VAISALA______________________________________________________________________ 191
Additional Range Checking
In addition to defining validity checking of the measured sensors (range
checks and step checks between consecutive measurements), you can
also add these checks for any other data, for example, calculated data or
data received via serial ports.
To add the value check component, proceed as follows:
1. Go to the Calculations view and select ValueCheck from the
available Misc calculations list.
2. Click the Add button to insert a new component.
3. Set the required values to parameters listed under Validation
parameters. Validation parameters are described in Table 25 on
page 192.
0711-110
Figure 95 Calculations View: Validation Parameters