Vaisala WAC151 Guida Utente Pagina 23

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 22
Chapter 6 _______________________________________________Technical Data
VAISALA__________________________________________________________21
CHAPTER 6
TECHNICAL DATA
This chapter provides technical data of WAC151 Cross
Arm.
Specifications
Table 4 WAC151 Cross Arm Specifications
Property Description / Value
I/O connectors Screw terminal connectors (15 pcs) for
the sensors and power lines.
Cable entries
Signal cable
Sensor cables
Totally four
Through a gland (for cable diameter
7 ... 10mm) with coaxial connectability
of the cable screen, for proper RF
shielding.
Through two rubber glands.
Thermostat switch
Connects at +4 °C (±3 °C)
Disconnects at +11 °C (±3 °C)
Mounting Clamp for a pole mast with a nominal
outside diameter 60 mm.
Material
Cross Arm
Junction Box
Al, anodized
Al, painted
Dimensions
Cross Arm length
Junction Box
800 mm
125 x 80 x 57 mm
Weight 1.5 kg (without sensors)