Chapter 4 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 35
discarded. Commands may include parameters and values which are
separated by a space ' '. Only one parameter can be set with a single
command; multiple parameters require multiple commands.
You can repeat the previous command by typing CTRL+P. The
previous command will be brought to the console, but it will not be
automatically executed. You can delete characters with the backspace
key [<=]. Arrow keys are not available for data editing, and tabulator
completion is not supported.
A list of the supported commands is provided in section List of Serial
Commands on page 35.
List of Serial Commands
The following table provides a list of the serial commands that are
available in the service connection.
Table 6 List of Serial Commands
Command Description
OPEN Open the service connection
CLOSE Close the service connection
HELP Display the command list
SETDEV Set the ID of the transmitter
SETMEA Configure measurement parameters
SETSPD Configure wind speed computation time period
SETDIR Configure wind direction computation time period
SETMES Specify data transmission mode
SETCOM Configure communication ports
SETALR Configure sensor stuck supervision functionality
SETHEA Configure wind sensor heating control
GETHEA Display the current heating status
SERVICE TIMEOUT Configure timeout for service connection
GETSET Display the current settings of the device
ERRS Display the current error status
INIE Reset the transmitter to factory default settings
RESET Reset the transmitter to new settings