Chapter 4 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 95
Changing Output Mode and Range
Both output channels have their own DIP switch module with 8
switches, see the position in Figure 2 on page 17. (DIP switches for
analog output settings.)
1. Select the current/voltage output, switch ON either of the
switches, 1 or 2.
2. Select the range, switch ON one of the switches from 3 to 7.
0503-045
Figure 40 Current/Voltage Switches of Output Modules
Numbers refer to Figure 40 above:
1 = Current/voltage selection output switches (from 1 to 2)
2 = Current/voltage range selection switches (from 3 to 7) in
analog output 1 and 2.
3 = Switches for service use only. Keep in OFF position always.
NOTE
Only one of the switches 1 or 2, must be ON at a time.
Only one of the switches 3 to 7, must be ON at a time.